DC, Pulsed DC or RF: Choosing a Plasma Power Supply by Material and Process

Why each type of power supply needs its own way of handling charge
Technical analysis of each power supply type
Comparing the three plasma power supply types
| Technical criterion | DC | Pulsed DC | RF |
|---|---|---|---|
| Power delivery | Constant one-directional negative voltage | Pulses, interrupted or briefly reversed | Radio-frequency alternating current (13.56 MHz) |
| Compatible materials | Conductive materials only | Conductive and semiconducting, strong in reactive sputtering | All materials, including insulators |
| Arcing risk | More likely, especially with a contaminated or oxidized surface | Lower, thanks to charge neutralization on each pulse | Lowest when processing insulating materials |
| Deposition rate | Very high | High | Lower than DC at the same power |
| Impedance matching network | Not needed | Not needed | Required |
| Investment and operating cost | Low | Medium | High |