- Sensor: HUMICAP 180L2
- Water Activity:
Measurement range aw (%RS): 0 … 1 (0 … 100 %)
Response time (90 %) at +20 °C in still oil (with stainless steel filter): 10 min
- Temperature:
Measurement range: -40 ... +180 °C (-40 ... +356 °F)
Typical accuracy at +20°C (68°F)L: ±0.2 °C (±0.36 °F)
- IP rating: IP66
- Two analog outputs, selectable and scalable:
0 ... 20 mA or 4 ... 20 mA
0 … 5 V or 0 … 10 V
1 … 5 V available through scaling
- Typical accuracy of analog output at +20°C: ±0.05 % full scale
- Operating voltage: 10 ... 35 VDC