Accuracy:±0.5 %FS @ 25 °C
Applications:Only air and non-aggressive dry gases
Burst pressure: 6 x FS
Compensated temperature:0…+50 °C
Connection (to meter):4-pole M12
Connection (to process):For ⌀ 6x1 mm (internal ⌀ 4 mm) and ⌀ 8x1 mm (internal ⌀ 6 mm) hoses. 2 inputs for differential probes, 1 input for absolute probes
Dimensions:⌀ 21.7 x 62 mm
Long-term stability:< 1 %FS / year
Material:Stainless steel
Operating conditions:-25…+85 °C / 0…95% RH non-condensing
Output:UART (TTL 3.3V)
Overall error:±2.5 %FS over the whole compensated temperature range
Overpressure:3 x FS
Power supply:3.3 ... 6 Vdc
Protection degree:IP65
Storage temperature:-40…+125 °C
Warm-up time:2.3 ms
Weight:74 g approx.
Measuring range:-2.500 ... +2.500 mbar
Cable connection:M12A connector, 4-pin
Calibration:Factory adjustment with test protocol
Compensated temperature range:0 ... +50 °C
Housing:Stainless steel
Option:1 m PVC connection cable M12
Pressure connection:2x connection for tube 6x1 mm (4 mm inner) or 8x1 mm (6 mm inner), differential
Protection: typeIP65
Version:Interchangeable without loss of accuracy
Working temperature:-25 ... +85 °C