Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Non-invasive Blood Pressure
Simulation Waveform: Oscillometric.
Integrated Pump: 0 to 350 mmHg, user configurable.
Leak Test: User configurable between 0-350 mmHg.
Chronometer: Configurable up to 999 secs.
Digital Manometer: 0 - 410 mmHg.
Pressure Accuracy: ± 0.5% FS.
Pressure Units: mmHg, inHg, kg/cm², cmH₂O, mBar, PSI, inH₂O, and kPa.
ECG Arrhythmia Simulator
ECG: 5 lead simulation, including high-level output.
Wave Forms: Normal Sinus Rhythm (NSR), ST Elevation, ST Depression, Myocardial Infarction, Tall T.
Rate: 20 – 300 BPM, typed value.
Performance Waveforms: Sine, Square, Triangle, and Pulse.
Pacer Waveforms: Synchronous Atrial, Asynchronous Atrial.
Pacer Only: Pacer Pulse rate 60 BPM, Ventricular Pacer rate 70 BPM, Atrial & Ventricular Pacer Heart rate 70 BPM, R Wave Detection.
Temperature
Simulation: YSI 400 / 700 Static.
Range: Preset at 25, 33, 37, and 41°C.
Invasive Blood Pressure
Channels: 2 channels.
Static: 0 to 300 mmHg, typed values.
Dynamic: 0 - 300 mmHg for systolic & diastolic.
Oxygen Saturation
Range: 50 to 100%.
Accuracy: ± 1 bpm.
Chronometer: Test option to test response time of SpO₂ monitor.
Arrhythmia Waveforms
Atrial: Sinus Arrhythmia (SA), Missing Beat, Atrial Flutter (AFLT), Atrial Fibrillation (AFB), Paroxysmal Atrial Tachycardia (PAT), Junctional Premature Contraction.
Atrial Conduction: First Degree AV Block, Second Degree AV Block - Mobitz I, Second Degree AV Block - Mobitz II, Third Degree AV Block, Right Bundle Branch Block (RBB), Left Bundle Branch Block (LBB), Left Anterior Hemiblock.
Ventricular: Premature Ventricular Contraction - Intermittent, Premature Ventricular Contraction – Continuous, Bigeminy, Trigeminy, Ventricular Flutter (VFLT), Ventricular Fibrillation (VFB), Ventricular Tachycardia (VTC), Right Focal PVC.
Respiration
Rates: 5, 10, 15, 30, 60, 120, 180 Breaths per Minute.
Base Resistances: 250, 500, 750, 1000 ohms.
Apnoea Simulation: 0 – 60 seconds duration, 0 – 300 seconds interval.
General Specification
Operation: Battery cell, in-situ charge.
Battery Charger: 110-230VAC, 50/60 Hz.
Battery Life: 4-24 hours testing depending on simulations.
Memory Capacity: Approximately 10,000 records.
Communication: Via Bluetooth.
Display: Monochrome, ¼ VGA full graphics.
Keypad: Alpha-numeric.
Weight: <1.5 kg.
Size (L x W x D): 270 x 110 x 75 mm / 10.5 x 4 x 3”.
Operating Conditions: 10-30°C, 0-90% RH - NC.
Storage Environment: -15°C to +60°C.
Environmental Protection: IP 40.