ACW
Output voltage range: 0.00~10.00kV
maximum(power)output: 1000VA(10.0kV 100mA)
Maximum rated current: 100mA
Current gear: 2mA、20mA、100mA
discharge waveform: sine wave
Output waveform distortion: ≤5%(No-load or pure resistance load)
testing time: 0.0S-999S 0=continuous test
DCW
Output voltage range: 0.00~10.00kV
maximum(power)output: 1000VA(10.0kV 100mA)
Maximum rated current: 100mA
Current gear: 2mA、20mA、100mA
discharge waveform: sine wave
testing time: 0.0S-999S 0=continuous test
voltmeter
scope: 0.00~10.00kV
accuracy: ±(5% + 3 Words)
resolution ratio: 10V
Displays the values: root mean square value
Ammeter
measuring range
Range1:0.1mA~2mA;
Range 2:2mA~20mA
Range 3:20mA~100mA
resolution rati: 2mA档:1uA; 20mA档:10uA;100mA档:0.1mA
certainty of measurement: ± (5% + 3 words) within the range
Calculagraph
range: 0.0S-999S
minimum resolution: 0.1S
accuracy: ±(1%+50ms)
PLC interface: Optional
Remote control interface: standard
Overall volume(D×H×W): 530mm×230mm×454mm
weight: About the 44.7KG
Random standard accessories: Power line RK00018, RK00015 high voltage test line, RK26103 grounding line