Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Type of registered radiation: gamma, neutron
Energy range: 20 KeV – 3 MeV
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 4.5 m:
At 8 km/h / At 20 km/h
241Am, MBq, (µCi): 1.5 (41) / 2.3 (62)
137Cs, MBq, (µCi): 0.16 (4.3) / 0.24 (6.5)
60Co, MBq, (µCi): 0.10 (2.7) / 0.15 (4.1)
57Co, MBq, (µCi): 0.20 (5.4) / 0.30 (8.1)
133Ba, MBq, (µCi): 0.10 (2.7) / 0.15 (4.1)
238U, g: 1300 / 1900
235U, g: 80 / 120
239Pu, g: 2.3 / 3.4
239Pu, g (4 cm Pb): 240 / 400
252Cf, neutron/s: 14000 / 24000
Number of detection units: 8 detectors
Weight:
one gamma detector: 120 kg
one neutron detector: 130 kg
control unit: 20 kg
Ingress protection: IP65
Mean recovery time: no more than 60 min
Mean service lifetime: no less than 8 years
Atmospheric pressure: from 84 to 106.7 kPa
Operating temperature: -30 up to +50°C
Humidity: up to 98 % at 40°C and lower, no moisture
Power source:
Primary: industrial AC network (115-230V range), 47/63 Hz frequency
Back-up: built-in accumulator battery, 12 V DC. Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
Power consumption: no more than 120 V•А.