TA167 Current probe specification (all accuracies stated at 23°C ± 1°C)
Nominal current : 2000 A AC peak or DC
Measuring range(s) : 200 A / 2000 A
Output sensitivity : 10 mV/A / 1 mV/A
Accuracy (0 - 200/1500 A) : ± 1% of reading ± 100 / ± 500 mA
Accuracy (1500 - 2000 A) : ± 5% of reading
Resolution : ± 100 / ± 500 mA
Frequency range : DC to 20 kHz (–1 dB)
Power supply : 9 V alkaline battery PP3, MN1604 or IEC 6LR61
Load impedance (min) : > 100 kΩ and ≤ 100 pF
Conductor size : 32 mm diameter
Operating temperature : 0°C to +50°C
Output cable and connectors : 2 m long coax terminated with safety BNC connector
Safety standards : EN61010-1:2001
EN61010-2-032:2002
EN61010-031:2002
300 V CAT III, Pollution Degree 2