For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.ID
0
Product image

PCE PCM 3 Single Phase Power Clamp meter (AC 1000A)

ModelPCM 3
OriginChina
Warranty12 months
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

- Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH

- Measuring function:

Current measurement AC:

Measuring range; Resolution; Accuracy

60 A; 0.01 A; ± 2% + 8 Dgt

600 A; 0.1 A; ± 2% + 8 Dgt

1000 A; 1 A; ± 2% + 8 Dgt

Maximum input current: 1000 A AC

Frequency range: 40 .... 400 Hz

- Measuring function:

Inrush current AC:

Measuring range; Resolution; Accuracy

60 A; 0.01 A; For reference only

600 A; 0.1 A; ± 5% + 60 Dgt

1000 A; 1 A; ± 5% + 60 Dgt

Integral time: 100 ms

Measuring range: 20 ... 1000 A

Frequency range: 40 .... 400 Hz

- Measuring function:

Voltage measurement DC:

Measuring range; Resolution; Accuracy

6V; 0.001V; ± 0.5% + 5 Dgt

60V; 0.01V; ± 0.5% + 5 Dgt

600V; 0.1V; ± 0.5% + 5 Dgt

1000V; 1V; ± 0.8% + 4 Dgt

Input impedance: 10 MΩ

Maximum input voltage: 750V AC (rms value) or 1000V DC

- Measuring function:

Voltage measurement AC:

Measuring range; Resolution; Accuracy

6V; 0.001V; ± 0.6% + 4 Dgt

60V; 0.01V; ± 0.6% + 4 Dgt

600V; 0.1V; ± 0.6% + 4 Dgt

1000V; 1V; ± 0.8% + 4 Dgt

Input impedance: 10 MΩ

Maximum input voltage: 750V AC (rms value) or 1000V DC

Frequency range: 40 ... 400 Hz

- Measuring function:

Frequency measurement with

The current measuring function

Measuring range; Resolution; Accuracy

99.99 Hz; 0.01 Hz; ± 1.5% + 5 Dgt

999.9 Hz; 0.1 Hz; ± 1.5% + 5 Dgt

Measuring range: 10 ... 1 kHz

Measuring range of the input signal: > 20 AAC (rms value)

The input current increases with the measuring frequency.

Maximum input current: 1000 AAC (rms value)

- Measuring function:

Frequency measurement with the

Voltage measurement function

Measuring range; Resolution; Accuracy

99.99 Hz; 0.01 Hz; ± 1.5% + 5 Dgt

999.9 Hz; 0.1 Hz; ± 1.5% + 5 Dgt

9,999 kHz; 0.001 kHz; ± 1.5% + 5 Dgt

Measuring range: 10 ... 10 kHz

Measuring range of the input signal: > 1V AC (rms value)

The input current increases with the measuring frequency.

Maximum input voltage: 1000V AC (rms value)

- Measuring function:

Frequency measurement :

Measuring range; Resolution; Accuracy

9,999 Hz; 0.001 Hz; ± 0.3% + 5 Dgt

99.99 Hz; 0.01 Hz; ± 0.3% + 5 Dgt

9,999 kHz; 0.1 Hz; ± 0.3% + 5 Dgt

999.9 Hz; 0.001 kHz; ± 0.3% + 5 Dgt

99.99 kHz; 0.01 kHz; ± 0.3% + 5 Dgt

999.9 kHz; 0.1 kHz; ± 0.3% + 5 Dgt

9,999 MHz; 0.001 MHz; ± 0.3% + 5 Dgt

Overvoltage protection: 1000V DC or 750V AC (rms value)

Range of voltage input> 2V

(as the input voltage increases, so does the frequency)

- Measuring function:

Duty cycle

Measuring range; Resolution; Accuracy

0.1 ... 99.9%; 0.1%; ± 0.3% + 5 Dgt

Frequency range: 10 ... 10 kHz

Voltage range: 2 ... 250V AC (rms value)

(The voltage increases with the frequency)

Duty cycle with the Current measurement function:

Frequency range: 10 ... 1 kHz

Input current: 20 ... 1000 AAC (rms value)

Duty cycle with the oltage measurement function:

Frequency range: 10 ... 1 kHz

Input current: 1 ... 750V AC (rms value)

Input impedance: 1MΩ

- Measuring function:

Resistivity

Measuring range; Resolution; Accuracy

600 Ω; 0.1 Ω; ± 0.8% + 3 Dgt

6 kΩ; 0.001 kΩ; ± 0.8% + 3 Dgt

60 kΩ; 0.01 kΩ; ± 0.8% + 3 Dgt

600 kΩ; 0.1 kΩ; ± 0.8% + 3 Dgt

6 MΩ; 0.001 MΩ; ± 2% + 5 Dgt

60 MΩ; 0.1 MΩ; ± 2% + 5 Dgt

Measuring voltage: approx. 0.78V

Overvoltage protection: 750V DC, 1000V AC (rms value)

- Measuring function:

Continuity test

Measuring range; Resolution; Accuracy

600 Ω; 0.1 Ω-

Acoustic signal at < 50 Ω

Test voltage: 1.48V

Overvoltage protection: 750V DC, 1000V AC (rms value)

- Measuring function:

Capacitance measurement

Measuring range; Resolution; Accuracy

9.999 nF; 0.001 nF; ± 3% + 5 Dgt

99.99 n.f.; 0.01 nF; ± 3% + 5 Dgt

999.9 nF; 0.1 nF; ± 3% + 5 Dgt

9.999 μF; 0.001 μF; ± 3% + 5 Dgt

99.99 μF; 0.01 μF; ± 3% + 5 Dgt

999.9 μF; 0.1 μF; ± 3% + 5 Dgt

9,999mF; 0.001 mF; ± 3% + 5 Dgt

99.99 mF; 0.01 mF; ± 3% + 5 Dgt

Overvoltage protection: 750V DC, 1000V AC (rms value)

- Measuring function:

Diode measurement

Measuring range; Resolution; Accuracy

3V ; 0.001V; -

DC anode side: approx. 1-mA

DC cathode side: approx. 3.2V

Overvoltage protection: 750V DC, 1000V AC (rms value)

- Measuring function:

Single phase power measurement

Measuring range; Resolution; Accuracy

3 W / VA / Var; 0.01 W / VA / Var; ± 3% + 5 Dgt

100 W / VA / Var; 0.1 W / VA / Var; ± 3% + 5 Dgt

4000 W / VA / Var; 1 W / VA / Var; ± 3% + 5 Dgt

10 kW / VA / var; 0.01 kW / VA / Var; ± 3% + 5 Dgt

100 kW / VA / var; 0.1 kW / VA / Var; ± 3% + 5 Dgt

750 kW / VA / var; 1 kW / VA / Var; ± 3% + 5 Dgt

Smallest measuring current: 1-mA

Smallest measuring voltage: 1V

- Measuring function:

Power factor capacitive / inductive

Measuring range; Resolution; Accuracy

0.1 ... 1; 0.001; ± 5% + 5 Dgt

Smallest measuring current: 1-mA

Smallest measuring voltage: 1V

- Measuring function:

Harmonics measurement

Measuring range; Accuracy

1; ± 3% + 10 Dgt

2 ... 6; ± 3.5% + 10 Dgt

7 ... 8; ± 4.5% + 10 Dgt

9 ... 10; ± 5% + 10 Dgt

11 ... 15; ± 7% + 10 Dgt

16 ... 20; ± 10% + 10 Dgt

Smallest measuring current: 1-mA

Smallest measuring voltage: 1V

The resolution depends on the voltage measuring range

- General specifications:

Measuring range: Automatically and manually adjustable

Maximum voltage range: 1000V DC or 750V AC

Maximum working height: 2000 m / 6561 ft

Display: LCD

Maximum display: 5999 Dgt.

Overrange: "OIL"

Measuring range underflow: "-OL"

Measuring rate: 3 Hz

Automatic shutdown: After 30 minutes

Power supply: 9V block battery

Battery indicator: Icon if the battery voltage is too low

Temperature coefficient: 0.1 x accuracy x °C / °F*

Operating conditions: 0 ... 40°C, 32 ... 104°F

Storage conditions: -10 ... 60°C, 14 ... 140°F

Dimensions: 238 x 92 x 50 mm / 9.4 x 3.6 x 2 in

Weight: About 420 g / < 1 lb (with batteries)

Delivery scope:

1 x Voltmeter PCE-PCM 3

1 x Transport bag

1 x Test lead set

1 x 9V block battery

1 x User manual

Datasheet


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts