Specifications
DC
Measuring range; Resolution; Accuracy
4V DC; 1 mV; ± (1.2% of Mw + 2 digits)
40V DC; 10 mV; ± (1.5% of Mw + 2 digits)
400V DC; 100 mV; ± (1.5% of Mw + 2 digits)
600V DC; 1V; ± (2% of Mw + 2 digits)
Input impedance: 10 MΩ
Overvoltage protection: 600V DC ; 600V AC RMS
AC
Measuring range Resolution; Accuracy
4V AC; 1 mV; ± (1.5% of Mw + 5 digits)
40V AC; 10 mV; ± (1.5% of Mw + 2 digits)
400V AC; 100 mV; ± (1.5% of Mw + 2 digits)
600V AC; 1 V; ± (2% of Mw + 2 digits)
Input impedance: 10 MΩ
Overvoltage protection: 600V DC; 600V AC RMS
Frequency range: 50 ... 400 Hz
Alternating current
Measuring; range Resolution; Accuracy
200 A AC; 100-mA; ± (3.0% of Mw + 5 digits)
Overload protection: 200 A AC
Frequency range: 50 ... 60 Hz
Resistance
Measuring range; Resolution; Accuracy
400 Ω; 0.1 Ω; ± (1% of Mw + 4 digits)
4 kΩ; 1 Ω; ± (1.5% of Mw + 4 digits)
40 kΩ; 10 Ω; ± (1.5% of Mw + 4 digits)
400 kΩ; 100 Ω; ± (1.5% of Mw + 4 digits)
4 MΩ; 1 kΩ; ± (2.5% of Mw + 4 digits)
40 MΩ; 10 kΩ; ± (3.5% of Mw + 4 digits)
Overvoltage protection: 250V DC; 250 AC RMS
Connection thermocouple: Type K connection with adapter
Capacity
Measuring range; Resolution; Accuracy
4 nF; 0.1 nF; ± (5% of Mw + 20 digits)
40 nF; 1 nF; ± (3% of Mw + 5 digits)
400 nF; 10 nF; ± (3% of Mw + 5 digits)
4 μF; 100 nF; ± (3% of Mw + 5 digits)
40 μF; 1 μF; ± (3% of Mw + 5 digits)
100 μF; 10 μF; ± (3% of Mw + 10 digits)
Overvoltage protection: 250V DC ; 250 AC RMS
Check feature: Test Display
Diode test: Test current: 0.5-mA
Reverse Voltage: 1.5V Forward voltage of the diode
Continuity test Open circuit Voltage 0.5V: Noise when resistance <50 Ω
Overvoltage protection: 250V DC; 250 AC RMS
Jaw Capacity: About 17 mm / .7 in
Display: 4000 digit LCD with backlight
Continuity test: Noise when resistance <50 Ω
Test current: About 0.5-mA
Open circuit voltage: <2V DC
Battery indicator: Battery icon when battery voltage low
Display overrange: OL appears in the display
Refresh rate display: 3 Hz
Temperature sensor: Thermocouple type K
Input impedance: 10 MΩ
Operating conditions: 5 ... 40°C / 41 ... 104°F, 80% rh non-condensing
Storage conditions: -20 ... 60°C / -4 ... 140°F, 80% rh non-condensing
Operating altitude: <2000 m
Power supply: 2 x 1.5V AAA battery
Automatic shutdown: 30 minutes
Security conditions:
IEC1010-1 (2001)
CAT II 1000V
CAT III 600V
Pollution degree 2
Dilivery Contents
1 x Clamp meter PCE-CM 3
2 x Test leads
2 x Measuring tip
1 x Adapter thermocouple
1 x Thermocouple type K
2 x AAA batteries 1.5V
1 x User manual