Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Memory: 2 GB
Weight: 390 g
Display: Yes
Protocol: Modbus
Baud Rate: 9600
Impedance: 900 Ω
Statistics: Average, Maximum, Minimum, Peak Hold, Valley Hold
Alarm modes: Adjustable, High, High/Low, Low
Data Format: 8 data bits:no parity:1 stop bit
Cable Length: 1 m
Current Draw: 100 mA
Display Size: 72 mm (2.8 in)
EMC Standard: EN61326-1, EN61326-2-4
File Formats: BMP
Relay Output: Single Pole, 24 Vdc, 1A
Accuracy Note: ± 1% of reading or ± 1ºC whichever is greater
Field of view: 20:1
Housing Width: 98 mm
Output Signal: Current
Response Time: 125 ms
Sampling Time: 1 to 86,400 sec
Data Interface: N/A
Housing Height: 64 mm
Housing Length: 36 mm
Supply Current: 50 mA
Supply Voltage: 5 Vdc
Emissivity, Min: 0.2
Variables Logged: Target temp, Sensing head temp, electronics module temp, max, min, average, emissivity setting, reflected energy compensation, alarm events
Cable Length Note: 1 m (3.3') (standard), up to 30 m (98.4') (optional)
Display Size Note: 72 mm (2.83") resistive touch TFT, 320 x 240 pixels, backlit
Supply Power Note: 5 Vdc (provided by USB)
Repeatability Note: ± 0.5% of reading or ± 0.5ºC whichever is greater
Response Time Note: t90 125 ms (90% response
Settable Parameters: Alarms, Data Logging, Date, Emissivity Setting, Modbus Address, Reflected Energy Compensation, Signal Processing, Temperature Range, Temperature Unit, Time
Sensing head Material: Stainless Steel
Internal Clock Battery: 1 x BR1225 3V (not included)
Relative Humidity Note: 95% max, non-condensing
Relative Humidity, Max: 0.95
Spectral Response, Max: 14 μm
Spectral Response, Min: 8 μm
Configuration Parameters: Number of Samples, Sample Period, Scheduled start date and time
Process Temperature, Max: 1000 °C
Process Temperature, Min: -20 °C
Emissivity Setting Method: None
Operating Temperature, Max: 75 °C