HH509R has all the same features as HH509
plus includes RS232 interface, cable, and software.
Thermocouple Range / Resolution :
K-TYPE : -200°C to 1372°C, -328°F to 1999°F / 0.1°C
J-TYPE : -210°C to 1200°C, -346°F to 1999°F / 0.1°C
T-TYPE : -200°C to 400°C, -328°F to 752°F / 0.1°C
E-TYPE : -220°C to 1000°C, -364°F to 1832°F / 0.1°C
S-TYPE : 0°C to 1767°C, 32°F to 1999°F / 1°C
Auto range: 0.1°C/1°C, 0.1°F/1°F.
Accuracy: Accuracy is specified for operating temperatures over the range of
18°C to 28°C (64°F to 82°F),not including thermocouple error.
±(0.1% rdg + 1°C) range -60°C to 1372°C
±(0.1% rdg + 2°C) range -60°C to -220°C
±(0.1% rdg + 2°F) range -76°F to 1999°F
±(0.1% rdg + 4°F) range -76°F to -364°F
S-TYPE
±(0.0% rdg + 2°C) on 0°C to 50°C
±(0.1% rdg + 1°C) on 50°C to 1767°C
±(0.0% rdg + 4°F) on 32°F to 122°F
±(0.1% rdg + 2°F) on 122°F to 1999°F
ENVIRONMENTAL
Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H.
Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H.
GENERAL :
Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999.
Polarity: Automatic, positive implied, negative polarity indication.
Overrange: -OL is displayed.
Zero: Automatic.
Reading Rate: one time per second.
Low battery indication:the " " is displayed when the battery voltage drops
below the operating level.
Measurement rate: 1 times/second.
Accuracy: Stated accuracy at 23°C±5°C, <75% relative humidity.
Dimensions: 195mm(H) x 92mm(W) x 53mm(D).
Weight: 365g.
Input Connector: Accepts standard miniature thermocouple connectors (flat
blades spaced 7.9mm, center to center).
Battery Life: 100 hours typical battery.
Auto power off: The meter key switch inactive for more than 30 minutes, press
power key to resume operation.
Temperature Coefficient: 0.1 times the applicable accuracy specification per °C
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F).
Input Protection: 24V dc or 24V ac rms maximum input voltage on any
combination of input pins.
Maximum Differential Common Mode Voltage (Maximum Voltage between
T1 and T2 during measurement): 1volt.