Voltage: 40V
Current: 800A
Power: 4000W
Min. Operating Voltage: 0.1V@400A/ 0.2V@800A
CC Mode:
Range: 0~80A/ 0~800A
Setting Resolution: 1mA/ 10mA
Setting Accuracy (23±5℃): Low range: 0.1%+0.1%F.S., High range: 0.1%+0.15%F.S.
CV Mode:
Range: 0~4V/ 0~40V
Setting Resolution: 0.1mV/ 1mV
Setting Accuracy (23±5℃): 0.05%+0.05%F.S.
CP Mode:
Range: 0~4000W
Setting Resolution: 0.1W
Setting Accuracy (23±5℃): 0.5%+1%F.S.
CR Mode:
Range: 0.001Ω~5Ω/ 0.02Ω~50Ω
Setting Resolution: 16bits
Setting Accuracy (23±5℃): 0.35%+64mS/ 0.35%+6.4mS
Slew Rate:
Current: 13.3~800A/ms/ 800~4000A/ms
Voltage: 0.334~16.7V/ms/ 16.7~166.7V/ms
Power: 13.3~800A/ms/ 800~4000A/ms
Resistance: 13.3~800A/ms/ 800~4000A/ms
Accuracy (23±5℃): (1±35%)* Setting value
Voltage Measurement:
Range: 0~4V/ 0~40V
Readback Accuracy: 0.05%+0.05%F.S.
Current Measurement:
Range: 0~80A/ 0~800A
Readback Accuracy (23±5℃): 0.1%+0.1%F.S.
Power Measurement:
Range: 0~4000W
Readback Accuracy (23±5℃): 0.5%+1%F.S.
Dynamic Mode:
T1&T2: 1~60000ms
Resolution : 1ms
Accuracy (23±5℃): 1ms+100ppm
Others:
Interface: LAN/RS232/CAN
AC Input: Single phase, 220V AC±10%, frequency 47Hz~63Hz
Communication Response Time: ≤10ms
Temperature: Operating temperature: 0℃~40℃, storage temperature: -20℃~60℃
Operating Temperature: Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net Weight: Approx. 32kg
Dimension: 6U, 265.0(H)*482.0(W)with handle*612.0(D)mm