-pH Range: -2.000 to 20.000 pH

Resolution: 0.1 / 0.01 / 0.001 pH

Accuracy: ± 0.003 pH

Calibration Points: Up to 5

Buffer Options: USA / NIST / Custom

-ORP Range: ± 2000 mV

Resolution: 0.1 mV

Accuracy: ± 0.2 mV

-Conductivity (EC) Range:

0.000 µS/cm to 20.00 mS/cm (k=0.1)

0.00 µS/cm to 200.0 mS/cm (k=1)

0.0 µS/cm to 2.000 S/cm (k=10)

Resolution: 0.05% of full scale

Accuracy: ± 0.6% of full scale; ± 1.5% of full scale > 18.0 mS/cm

Reference Temperature: 15 to 30 °C (Adjustable)

Temperature Coefficient: 0.00 to 10.00 % (Adjustable)

Cell Constant: 0.1 / 1.0 / 10.0 (Selectable)

Measurement Unit: μS/cm, mS/cm, S/m (Auto-ranging / Manual)

Calibration Points: Up to 4 (Auto / Manual)

-TDS Range: 0.00 mg/L to 100 g/L

Resolution: 0.01 mg/L

Accuracy: ± 0.1% of full scale

Calibration Curves: EN27888 / 442 / Linear (0.40 to 1.00) / NaCl

-Resistivity Range:

0.0 Ω•cm to 2.000 MΩ•cm (k=10)

0.000 kΩ•cm to 20.00 MΩ•cm (k=1)

0.00 kΩ•cm to 200.0 MΩ•cm (k=0.1)

Resolution: 0.05% of full scale

Accuracy: ± 0.6% of full scale; ± 1.5% of full scale > 1.80 MΩ•cm

-Salinity Range: 0.00 to 100.00 ppt / 0.000 to 10.000 %

Resolution: 0.01 ppt / 0.001 %

Accuracy: ± 0.2% of full scale

Calibration Curves: NaCl / Seawater

-Temperature Range: -30.0 to 130.0 °C

Resolution: 0.1 °C

Accuracy: ± 0.4 °C

Calibration Option: Yes

Memory Data: 999

Auto Log Data: Yes

Real-time Clock: Yes

Date / Time Stamp: Yes

Auto-Shut Off: Yes (Programmable: 1 to 30 minutes)

Auto-Hold / Auto-Stable: Yes

Offset / Slope Display: Yes (Independent acid and alkaline slopes depending on calibration)

Electrode Status: On screen display

Diagnostic Messages: Yes

Calibration Alarm: Yes (Programmable: 1 to 400 days)

Display: Custom black and white static LCD, Dual Channel

Inputs: Dual BNC, dual phono, DC sockets

Output: RS232C, USB

Power Requirement: AC adaptor, 100-240V, 50/60Hz

Weight: 500g

Dimensions: 170(L) x 174(D) x 73(H) mm

Kit*

PC1100-S (3999960180)

• PC1100 meter

• electrode stand

• power adaptor

• 9615S-10D - refillable, glass-body pH electrode with integrated temperature sensor, 1m cable, BNC & phono jack

• 9382-10D - plastic-body, k=1.0 conductivity cell with integrated temperature sensor, 1m cable, BNC & phono jack

• pH 4.01, 7.01, 10.01, 3.33M KCl solutions (250ml ea)

• 84uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm solutions (250ml ea)


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support