Delivery Available

Input Ratings

Power type: Single-phase ; Three-phase, Delta or Y connection selectable

Voltage range: 200 Vac to 240 Vac ±10 % phase voltage (Delta: L-L, Y: L-N)

Frequency range: 47 Hz to 63 Hz

Power factor: 0.95 or higher (typ.)

Efficiency: 80 % or higher

Maximum power consumption: 8 kVA or lower


AC Output: Multi-phase output

*Single-phase output

Output capacity: 6kVA

Mode: IP2W

Setting mode: --

Phase voltage:

- Setting range:0.00 V to 175.0 V / 0.0 V to 350.0 V (sine and square wave), Setting Resolution: 0.01 V / 0.1 V

0.00 Vpp to 500.0 Vpp / 0.00 Vpp to 1000 Vpp (triangle and arbitrary wave), Setting Resolution: 0.01 Vpp / 0.1 Vpp / 1 Vpp

- Accuracy: ±(0.3 % of set + 0.5 V / 1 V)

Line Voltage Setting range: --

Maximum current: 60A/30A

Maximum peak current: Four times of the maximum RMS current

Load power factor: 0 to 1 (leading phase or lagging phase, 45 Hz to 65Hz)

Frequency:

- Setting range: AC Mode: 15.00 Hz to 2000.0 Hz, AC+DC Mode: 1.00 Hz to 2000.0 Hz, Setting resolution: 0.01 Hz / 0.1 Hz

- Accuracy: ± 0.01% of set

- Stability: ± 0.005%

Output on phase setting range: 0.0° to 359.9° variable (Free / Fix selectable), 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 2000 Hz)

Output off phase setting range: 0.0° to 359.9° variable (Free / Fix selectable), 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 2000 Hz)

Setting range of the phase angel: --

Phase angle accuracy: --

DC offset:± 20 mV (typ.)

* Polyphase output

Output capacity: 1P3W: 4 kVA ; 3P4W: 6 kVA

Mode: 1P3W ; 3P4W (Y-connection)

Setting mode: Independ, Balanced

Phase voltage:

- Setting range:0.00 V to 175.0 V / 0.0 V to 350.0 V (sine and square wave), Setting Resolution: 0.01 V / 0.1 V

0.00 Vpp to 500.0 Vpp / 0.00 Vpp to 1000 Vpp (triangle and arbitrary wave), Setting Resolution: 0.01 Vpp / 0.1 Vpp / 1 Vpp

- Accuracy: ±(0.3 % of set + 0.5 V / 1 V)

Line Voltage Setting range:

- 1P3W: 0.00 V to 350.0 V /0.00 V to 700.0 V3P4W: 0.00 V to 303.1 V /0.00 V to 606.2 V(sine and square wave)

Setting Resolution: 0.01 V /0.1 V

- 1P3W: 0.00 Vpp to 1000 Vpp /0.00 Vpp to 2000 Vpp3P4W: 0.00 Vpp to 866.0 Vpp /0.00 Vpp to 1732 Vpp(triangle and arbitrary wave)

Setting Resolution: 0.01 Vpp /0.1 Vpp / 1 Vpp

Maximum current: 20A/10A

Maximum peak current: Four times of the maximum RMS current

Load power factor: 0 to 1 (leading phase or lagging phase, 45 Hz to 65Hz)

Frequency:

- Setting range: AC Mode: 15.00 Hz to 2000.0 Hz, AC+DC Mode: 1.00 Hz to 2000.0 Hz, Setting resolution: 0.01 Hz / 0.1 Hz

- Accuracy: ± 0.01% of set

- Stability: ± 0.005%

Output on phase setting range: 0.0° to 359.9° variable (Free / Fix selectable), 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 2000 Hz)

Output off phase setting range: 0.0° to 359.9° variable (Free / Fix selectable), 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 2000 Hz)

Setting range of the phase angel:(polyphase output)

- 1P3W: L2 phase: 0° to 359.9°

- 3P4W: L2 phase: 0° to 359.9°

L3 phase: 0° to 359.9°

Setting Resolution: 0.1°

Phase angle accuracy (polyphase output):

45 Hz to 65 Hz: ±1.0°

15 Hz to 2000 Hz: ±2.0°

DC offset:± 20 mV (typ.)


DC Output ( Only single Phase output)

Output capacity: 6kW

Mode: Floating output, the N terminal can be grounded

Voltage:

-Setting range:-250.0 V to +250.0 V / -500.0 V to +500.0 V, Setting Resolution: 0.01 V / 0.1 V

- Accuracy: ±(|0.3 % of set| + 0.3 V / 0.6 V)

Maximum Current: 60A/30A

Maximum peak current: Four times of the maximum current


Output stability, total Harmonic Disortion, Output voltage time and Ripple noise

Line regulation: ±0.1% or less (Phase voltage)

Load regulation:

±0.1 V / ±0.2 V, @DC (only single-phase output)

±0.1 V / ±0.2 V, @45 Hz to 65 Hz (phase voltage, 0 to 100%, via output terminal)

±0.5 V / ±1.0 V, @all other frequencies (phase voltage, 0 to 100%, via output terminal)

Disortion of output: <0.3 % @1Hz to 100Hz, <0.5 % @100.1 Hz to 500 Hz, <1 % @500.1 Hz to 2000 Hz

Output voltage respone time: Fast: 50 µs (typ.) ; Middle: 100 µs (typ.) ; Slow: 300 µs (typ.)

Ripple noise: 0.5 Vrms / 1 Vrms (TYP)



Standard Accessories

QuickStart Guide

Safety guide

Input terminal cover

Output terminal cover

Copper plate for delta connection input (Mark 1)

Copper plate for single phase and Y connection input (Mark 2)

Copper plate for delta connection input (Mark 3)

Copper plate for 1P output (Mark 4)

GRA-451-E Rack mount adapter (EIA)

USB cable (USB 2.0 Type A - Type B cable, approx. 1.2M)

Datasheet


Manual


Brochure

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support