Power supply
- Voltage: 3×230/400V±10%
- Frequency: 50/60Hz±2Hz
- Power capacity: >6kVA
Voltage
- Test voltage output (Phase-Neutral): 3×(24V–480V) or 600V F-F customized
- Power of the voltage output: 3×800VA
- Resolution: Better than 0.01% of the full-scale value of the range
- Setting accuracy: Better than 0.05% at the final range value
- Stability: Better than 0.005%/h (integration time 150s)
- Load regulation from 0-max. load: <0.01%
- Distortion factor: <0.3% for linear resistance load
- Harmonics: 2nd-41st free programmable
Current
- Test current output: 1mA-120A
- Power of the current output: 3×1200VA
Phase angle
- Range: 0°-360°
- Resolution: 0.01°
- Setting accuracy: 0.1°
Frequency
- Range: 45 Hz – 65 Hz
- Resolution: 0.01 Hz