Power: 20W/ 100W
Current: 0~2A/ 0~20A
Voltage: 0~80V
Typical Min. Operation Voltage (DC):
0.4V@1A/ 0.4V@10A
0.8V@2A/ 0.8V@20A
Constant Current Mode
Range: 0~2A/ 0~20A
Resolution: 0.5mA/ 5mA
Accuracy: 0.1%+0.1%F.S./0.1%+0.2%F.S.
Constant Resistance Mode
Range:
0.075Ω~300Ω (100W/16V)
3.75Ω~15kΩ (100W/80V)
Resolution:
3.333mS (100W/16V)
66.667µS (100W/80V)
Accuracy:
300Ω: 0.1S + 0.2%
15kΩ: 0.01S + 0.1%
Constant Voltage Mode
Range: 0~80V
Resolution: 20mV
Accuracy: 0.05% + 0.1%F.S
Constant Power Mode
Range: 0~20W/ 0~100W
Resolution: 5mW/ 25mW
Accuracy: 0.5% + 0.5%F.S.