Measurement range: 0~25.00% O2
Accuracy:
0.01%~0.1%: ±3%FS
0.01%~1%: ±3%FS
0.01%~25%: ±2%FS
Repeatability:
0.01%~0.1%: ±1.5%FS
0.01%~1%: ±1.5%FS
0.01%~25%: ±1%FS
Stability: ±1% FS/7d
Response time: T90<30s (after full preheating)
Power supply: 24VDC,7A
Relay contact capacity: 24VDC,0.2A (optional alarm)
Communication: RS232 (Standard)/RS485(optional)
Sensor life: More than 2 years (normal use)
Sensor model: GYB4.9
Ambient temperature of meter: -10~60°C
Ambient temperature of probe: CI-PC191 is 0~500°C,CI-PC191-1 is 0~180°C
Header size: L×W×H=158mm×158mm×99.5mm
Probe insertion depth: 600mm,800mm,1000mm,1200mm,1500m m,1800mm Can be customized according to user needs
Sensor warm up time: About 2 minutes.
Probe tube outer diameter: Φ40mm