For full functionality of this site it is necessary to enable JavaScript.
EMIN.CO.ID
0

Air Quality Meters and the Key Parameters to Monitor

08/18/2026 15:15:28

Monitoring CO₂, fine particulate matter, and other relevant parameters with an air quality meter helps identify changes that may be difficult to detect through human senses alone.

A room that feels cool and has no unusual odor does not necessarily have good air quality. Indoor air conditions change depending on the number of occupants, usage time, pollution sources, and ventilation systems. These changes are not always visible or noticeable. 

An air quality meter can be used to monitor multiple parameters, including oxygen, CO₂, temperature, humidity, and fine particulate matter.

CO₂ Can Rise in Enclosed Spaces

People continuously release CO₂ through respiration. The more people occupy a room and the longer they stay, the more CO₂ is generated.

An air conditioning system can maintain a comfortable temperature even when the amount of fresh air supplied to the room is limited. Therefore, temperature and personal comfort alone are not sufficient to assess indoor air quality.

A CO₂ gas detector measures changes in CO₂ concentration in ppm, providing useful data for evaluating ventilation while the room is occupied.

CO₂ and Fine Dust Are Different

An increase in CO₂ does not necessarily mean that fine particulate levels will also increase, and the opposite is also true.

A particulate matter meter is often used together with a CO₂ gas detector when assessing indoor air quality.

CO₂ is mainly associated with human respiration and air exchange.

PM2.5 and PM10, on the other hand, can come from vehicle exhaust, cooking, outdoor air pollution, building materials, or other indoor sources.

A room can have an acceptable CO₂ concentration while still recording high PM2.5 levels if the outdoor air is polluted or there is an indoor source of particulate matter.

Air Quality Meter

Where Should an Air Quality Meter Be Placed ?

The location of the measuring device can affect the results.

An air quality meter should be placed in an area representative of where people live or work. It should not be positioned directly next to windows, doors, air supply outlets, or local sources of particulate matter.

If a room has several occupied areas with different airflow patterns, measurements may need to be taken at several locations before selecting a fixed monitoring point.

For a fine particle counter, the device should also be kept away from a localized dust source when the purpose is to assess the overall air quality of the room.

When Is Continuous Monitoring Needed ?

A single measurement taken when a room is empty only reflects the conditions at that particular time. As the number of occupants increases, doors remain closed, or ventilation conditions change, air quality parameters can also change.

In offices and meeting rooms, monitoring should ideally be carried out while the space is occupied. If CO₂ continues to rise for several hours and decreases slowly after ventilation is increased, the data can be used to evaluate the fresh-air supply system.

Monitoring fine particulate matter over time can also help identify when concentrations increase, such as during cooking, cleaning, door opening, or when outdoor dust enters the room.

Time-series data reveals trends rather than providing only a single measurement. For example, CO₂ may gradually increase from the beginning of the workday, reach a higher level midway through the session, and then decrease after doors are opened or ventilation is increased. For fine particulate matter, the device can record periods when PM2.5 concentrations rise sharply.

This data from an air quality meter can help determine whether the issue is related to insufficient air exchange, a particulate source, or the operation of the ventilation system.

An air pollution meter should be selected according to the pollution sources that need to be monitored and the actual measurement conditions, rather than simply based on the number of parameters the device can measure.

Related News

Insulation Resistance Tester: Procedures and Safety Precautions
08/25/2026 09:05:54

A megohmmeter must be used according to the proper procedure to ensure operator safety and reliable measurement results. This article covers its operating principle, testing procedure, influencing factors, and essential safety precautions.

How to Measure Ground Resistance Effectively
08/25/2026 09:02:07

A ground resistance tester is used to measure the resistance of a grounding system or ground electrode. Using the correct measurement method gives operators a better basis for identifying changes in the system over time and taking appropriate inspection or corrective measures.

DC Resistance Meter and Considerations When Testing Electrical Equipment
08/25/2026 09:00:32

DC resistance meters are commonly used to evaluate current paths, windings, and contact points characterized by low resistance. The results depend not only on the test object itself but also on the connection configuration, thermal state, inductive characteristics of the windings, and the current injection process.

DC Resistance Meter: Principles and Applications
08/25/2026 08:58:25