Number of outputs: 3
Voltage Range
Output 1 and 2: from 0V to 42V
Output 3: from 0V to 6V
Current Range: From 1mA to 6A
Power per output:
Output 1 and 2: 105W
Uscita 3: 36W
Total Power: Up to 246W
OUTPUT SETTING & CONTROL
Output Setting:
Direct entry of output voltage or current via touch control with on screen numeric keypad.
Individual V & I rotary knobs for simultaneous adjustment of output voltage and current settings.
Operating Mode: Constant voltage (CV) or constant current (CC) or constant power (CP) with automatic crossover
Output Switch
Independent electronic switching with LED ON indication.
In addition, each output key actions Multi-On and Multi-Off (if enabled from instrument menu).
Output discharge by weak internal pull-down.
Output sense: Selectable local or remote sensing.
Setting Resolution: 1mV, 1mA
Setting Accuracy:
Voltage: ± (0.1% of setting + 5mV)
Current: ± (0.1% of setting + 5mA)
Instrument Control: Instrument settings can be set using touch or V rotary knob to navigate, and press knob to confirm.
Status Indication: Indicators for Output ON, constant voltage mode, constant current mode, remote operation, trip & error messages on display.
OUTPUT CONNECTIONS:
Output Terminals: Front panel: Universal 4mm safety binding posts on 19mm (0.75”) spacing.
OUTPUT PERFORMANCE
Ripple & Noise (20MHz bandwidth):
Typically <2mV rms, <10mV pk-pk. 22mV pk-pk max for maximum load CV mode
Typically<2mA rms, <10mA pk-pk. 15mA pk-pk max for maximum load CC mode
HF Common Mode Noise (20MHz bandwidth): Typically <4mV rms, <30mV pk-pk , 50mV pk-pk max (Into 560ohm)
Load Regulation:
For any load change within the PowerFlex envelope, using remote sense:
Constant voltage (CV): <0.01% ± 5mV
Constant current (CC): <0.01% ±0.5mA
Line Regulation:
For a 10% line voltage change:
Constant voltage (CV): <0.01% ± 5mV
Constant current (CC): <0.01% ± 0.5mA
Transient Response:
To within 100mV of setting for a 5% to 95% load change: Typically <350µsec. Maximum 375µsec.
GENERAL
AC Input: 110V to 240V AC +/- 10%, 50/60Hz. Installation Category II
Power Consumption: 360VA maximum
Operating Range: 5°C to +40°C, 20% to 80% RH
Storage Range: –40°C to +70°C
Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2
Output Isolation: 150V pk to Ground
Size: 214 x 140 x 300mm (WxHxD)
Weight: <4 kg